Laser Repair near Leicester, on a Chinese Red Laser and a Lotus Laser BLU125 Machine – Three Point
A visit to our customer, Three Point was requested as the customers had said that they had to significantly slow down their Red laser in order to cut through material and the BLU125 Lotus Laser System was having renewed intermittent interlock issues. The laser repair was conducted by our highly experienced service engineer ‘Gavin Edwards’. The laser service visit included: –
Upon arrival at Three Point the machines was visually inspected. The laser machines were in different conditions and so the laser power issues on the generic Chinese laser machine were investigated first: –
Red Laser – 100watt
To start the inspection, the laser power was tested and measured at the exit aperture of the laser nozzle. It was shown to be measuring 50w @99% power. Due to the age of the laser PSU and laser tube, it was decided that both would be replaced.

A new Reci W4 was installed along with an appropriate 100watt laser PSU.


The laser beam was adjusted and aligned into all 4 corners and in the centre of the working area.
Following the renewed laser tube and power supply. The rest of the machine was serviced. The main focusing lens was a 4″ lens and this was inspected and cleaned. The mirrors were inspected and cleaned. Mirror 1 had to be replaced as the mirror was tarnished. The mirror in question was the Si Gold variety. These can tarnish quiet easily and not ideal for industrial open aired laser units. The mirror was replaced with a Molybdenum mirror. As these are highly versatile and very robust to dirt and contamination.

The service continued with the following items with little to no issues
- Inspected and cleaned laser nozzle
- Cleaned fan filters
- Drained, Flushed and Refilled Chiller unit
- Inspected, cleaned and lubricated linear bearings
- Inspected and cleaned electrical bay
- Inspected and tested all sensors
After the servicing had been completed the laser power was once again measured at the output to the laser nozzle. This was now measuring 97w @99% power.
The machine was tested by running some of the customer previous jobs on the machine, all tested ok and the customer was happy with the results.

Lotus Laser – BLU125 – 100watt
The laser service could now move onto the Lotus laser System machine and the advised issue of the intermittent interlock issue.
The main door to the machine was inspected and the right hand gas strut was found to be loose. This caused the main door to move when opening and closing it. This was demonstrated to be causing the intermittent fault by showing that the sensor would sometimes pickup the door and sometimes not, indicating the intermittent nature of who and how the door was being opened and closed. The piston strut was tightened and the door and interlock tested. This was shown to fix the fault.
Not the fault had been rectified, the service on the machine could now be carried out.
All mirrors and the main focusing lens were inspected and cleaned. The 2.5″ focusing lens was shown to be damaged around the edge of the lens, but would not be effecting performance. A spare lens was left with the customer in case the unit happened to fail in between laser services.

The service continued with the following items with little to no issues
- Checked laser alignment
- Inspected and cleaned laser nozzle
- Cleaned fan filters
- Drained, flushed and refilled chiller unit
- Inspected, cleaned and lubircated linear bearings
- Inspected and cleaned electrical bay
- Inspected and tested all sensors
It was noted that even though the safety interlocks were all now working that the red spanner indicator on the front of the machine was still illuminated. All wiring on the electrical cabinet were checked, including pull tests on the cables, no issues were found. Voltage checks on all three power supplies were carried out and were within normal specifications. The machine is fitted with a PLC which was indicating that a laser service is due.

This is likely the reason why the red spanner illumination remains lit. This is something that only Lotus Laser can reset which unfairly, in our opinion, ties you to Lotus Laser for clearing the notice. However it does not affect the overall operation of the machine and therefore is not an operational issue for customers.
After the servicing had been completed the laser power was once again measured at the output to the laser nozzle. This was now measuring 93w @90% power.
The machine was tested by running some of the customer previous jobs on the machine, all tested ok and the customer was happy with the results.

Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser Repair near Leicester capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.
Contact Us for Laser Engraving, Marking & Cutting Ad
Frequently Asked Questions:
How do I improve Inconsistent Cutting Depth?
Verify that the laser head is correctly focused for the material’s thickness
Check for debris or dust on the mirrors and lenses.
Ensure that the cutting bed is level across the entire work area.
How do I stop the laser from cutting unevenly?
Inspect and clean the optical components (mirrors and lenses).
Check that the work bed is level; an uneven bed will affect cutting depth.
Ensure the material is flat and secured in place on the bed.
How to stop the laser head dragging on Material
Ensure that the material is flat and not bowed or warped.
Check the height adjustment of the laser head and set the correct z-axis distance.
Verify that the workpiece is secured properly on the bed.