A visit to a customer, The Forest School was required as the customer had reported that the laser machine was not moving along the X – Axis. whilst on site the customer also requested their annual laser service on their flatbed laser machine, which we would recommend for all our customers. The laser service was conducted by our highly experienced service engineer ‘Gavin Edwards’. The service visit included: –
Technology Supplies 6090
Upon arrival at The Forest School the flatbed machine was visually inspected. The machine was in good condition.
The repair of the laser machine was then started. The laser head was attempted to be moved manually in the X axis. This caused alot of resistance in the laser head. This pointed towards a short in the wiring between the motor and the servo driver. Removed and checked the cable and it was shown that there was indeed a short in the wiring. This wiring loom was replaced.
Whilst replacing this cable it was noted that a previous repair had taken place by a different company to repair the X limit Sensor and the auto focus tool. It was also noted that the red diode pointer was not working. All wiring looms were replaced with new for these three items, through the cable chains and back to the Ruiida controller.


Once all the looms had been completed the function of the machine was tested. The X-Axis and the other 3 items were now working as expected.
The following remaining items of the service were carried out with no issues: –
- Inspect and Clean all Mirrors and Lens
- Water Cooling Chiller Inspection, Clean, Drain & Refill
- Inspect, Clean and Lubricate all Linear/Guide Rails
- Calibrate Bed Level
- Electronics Inspection
- Safety Interlocks Inspection & Test
The laser alignment was checked but was found to be good in all the testing criteria. The laser power was measured and was shown to be 90.2w @25mA 88%. The service of the laser machine was now completed and the customer files were tested on the machine. The customer was happy with the service.

As part of the extended laser machine service that Thinklaser offers, we also inspect the extraction units of all our customers. In this case there was a strong smell of acrylic coming from the extraction unit. Upon further inspection the Combined Filter was dated August 2017 and the Pre-filter was dated Sept 2022. The pre-filter was showing only half full. The customer did have an additional inline fan connected to the extraction units exhaust port, but there was still a smell of acrlyic with this on. It was recommend to change the Combined Filter.


Being a part of a school the customer does all sort of jobs on their machine, Below are some of their items produced: –



Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser Repair near Horsham capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.
Contact Us for Laser Engraving, Marking & Cutting Advice
Frequently Asked Questions:
How do I improve Inconsistent Cutting Depth?
Verify that the laser head is correctly focused for the material’s thickness
Check for debris or dust on the mirrors and lenses.
Ensure that the cutting bed is level across the entire work area.
How do I stop the laser from cutting unevenly?
Inspect and clean the optical components (mirrors and lenses).
Check that the work bed is level; an uneven bed will affect cutting depth.
Ensure the material is flat and secured in place on the bed.
How to stop the laser head dragging on Material
Ensure that the material is flat and not bowed or warped.
Check the height adjustment of the laser head and set the correct z-axis distance.
Verify that the workpiece is secured properly on the bed.