Laser Machine Service near Selsdon, on a HPC 6090 – 60w and a 4060 – 50w LaserScript Machines – Croydon High School for Girls
A visit to our new customer, Croydon High School for Girls was required as the customer was requiring a service on their aging laser machine, as the customer was unable to cut through 3mm acrylic. We recommend a yearly service for all our customer to keep their machines running at peak performance. The HPC service was conducted by our highly experience service engineer ‘Gavin Edwards’. The laser service visit included: –
Upon arrival at Croydon High School for Girls, both the 6090 and the 4060 HPC Laserscript machines were visually inspected.
HPC Laserscript 6090 – 60W
The customer had informed us prior to our visit that the customer had removed the lens tube assembly but was unable to refit the unit together again. The laser head was removed and the threads cleaned and redressed. Following this clean up the lens tube could be reattached and was secured in place.

Now that the this issue had been completed the service could be started.
- Inspect and Cleaned all mirrors and focusing lens – Mirrors were heavily contaminated
- Checked beam alignment
- Inspect and Hoovered out the laser chamber and bed area and extraction port
- Inspect, Drain and Refill Chiller cooling circuit
- Electronics Inspection
- Check Bed Level
- Checked belts, linear bearings and rails
- Check the field scale calibration of both X and Y axes.
- Safety Interlocks Inspection & Test
- Check overall machine function by Test Cutting Customer Materials
Whilst performing the final checks on the machine, it was found that one of the lid hinges had not been secured with a retaining pin. This was re-positioned and secured in place.
Also whilst running some lasering trials it was noted that there was a strong smell coming from the AD Oracle extraction unit. On closer inspection it was noted that the filters were getting old and due to the smell the active carbon had been used up or depleted. Both the combined filter and the pre-filter were recommended to be replaced

The laser power was measured at the exit aperture to the nozzle. It was shown to be measuring 69.1w @80% power. This concluded the repair and service of the HPC 6090 Laserscript.

HPC Laserscript 4060 – 50W
The customer had informed us prior to our visit that the laser machine was not cutting or marking effectively. The service was first carried out, as sometimes this shows the causes behind cutting or marking issue: –
- Inspect and Cleaned all mirrors and focusing lens
- Checked beam alignment – Was out on the right side of the bed, adjusted into full alignment all over the bed
- Inspect and Hoovered out the laser chamber and bed area and extraction port
- Inspect, Drain and Refill Chiller cooling circuit
- Electronics Inspection
Whilst performing the electrical inspection. It was noted that the machine was fitted with a Leetro controller and that the buttons on the HMI were working intermittently. It was recommended to the customer to upgrade the HMI and controller to a newer Ruida controller, which would allow the system to work with either RDworks or Lightburn.
- Check Bed Level
Whilst inspecting the bed level, it was found that the bed was uneven due to acrylic pieces underneath the right side of the bed. These were removed and the bed was levelled.
- Checked belts, linear bearings and rails
- Check the field scale calibration of both X and Y axes.
- Safety Interlocks Inspection & Test
Whilst inspecting the safety aspects of the machine is was noted that the piston struts which hold the lid securely in place, were very weak and barely supporting the lid, this could cause serious injury as the lid is a heavy metal object and if the piston struts give way could land on any person or persons beneath. It was recommended to replace them straight away.


The laser power was measured at the exit aperture to the nozzle. It was shown to be measuring 54.4w @85% power. This concluded the repair and service of the HPC 4060 Laserscript.

To complete the service several jobs were run on the machine to check it’s overall function.. and the teacher at Downsend School was happy with the results.
Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser Machine Service near Selsdon capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.
Contact Us for Laser Engraving, Marking & Cutting Ad
Frequently Asked Questions:
How do I improve Inconsistent Cutting Depth?
Verify that the laser head is correctly focused for the material’s thickness
Check for debris or dust on the mirrors and lenses.
Ensure that the cutting bed is level across the entire work area.
How do I stop the laser from cutting unevenly?
Inspect and clean the optical components (mirrors and lenses).
Check that the work bed is level; an uneven bed will affect cutting depth.
Ensure the material is flat and secured in place on the bed.
How to stop the laser head dragging on Material
Ensure that the material is flat and not bowed or warped.
Check the height adjustment of the laser head and set the correct z-axis distance.
Verify that the workpiece is secured properly on the bed.