Laser Machine Service near Bridgewater, Thinklaser 6090 80 watts – Novolex – Waddington Group
A visit to a current customer, Waddington Europe was required as the customer had requested their annual laser service on their laser machine, which we would recommend for all our customers. The laser service was conducted by our highly experienced service engineer ‘Gavin Edwards’. The laser service visit included: –
Thinklaser Lightblade 6090 80 watt
Upon arrival at Waddington Europe the flatbed machine was visually inspected. The machine was in good condition. The laser grill that is attached to the main door to enable air flow into the unit but to prevent laser radiation being visible through the grills had been removed. The auto focus bracket and the red diode pointer were not being used and secured out of the way of the laser nozzle.
The following items of the service were carried out with no issues: –
- Nozzle Inspection & Clean
- Inspection and cleaning of all mirrors and focusing lens
- Inspect, Clean and Lubricate all Linear/Guide Rails
- Calibrate Bed Level
- Checked all Sensor and switches
- Electronics Inspection
- Safety Interlocks Inspection & Test
The beam realignment was checked and was accurate. The laser powered was measured and was shown to be 89.9w @25mA 66%.
The LED lighting strip was found to be not working, so this was replaced with a new LED strip. The customer had originally bought a Purex extraction system but were now no longer using the system as they had plumbed in their own industrial extraction system to the uni.


Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser Machine Service near Bridgewater capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.
Contact Us for Laser Engraving, Marking & Cutting Ad
Frequently Asked Questions:
How do I improve Inconsistent Cutting Depth?
Verify that the laser head is correctly focused for the material’s thickness
Check for debris or dust on the mirrors and lenses.
Ensure that the cutting bed is level across the entire work area.
How do I stop the laser from cutting unevenly?
Inspect and clean the optical components (mirrors and lenses).
Check that the work bed is level; an uneven bed will affect cutting depth.
Ensure the material is flat and secured in place on the bed.
How to stop the laser head dragging on Material
Ensure that the material is flat and not bowed or warped.
Check the height adjustment of the laser head and set the correct z-axis distance.
Verify that the workpiece is secured properly on the bed.