Laser Machine Repair near Wimbledon, on a 1290 80 watt HPC LaserScript Machine – Wimbledon High School
A visit to a customer, Wimbledon High School was required as the customer had reported a fire with their HPC laserscript machine. The fire had happened whilst the machine was being used to cut corrugated cardboard. We were tasked with carrying out an inspection of the HPC laserscript to ensure that the machine was fully functional, and if we found issues to then repair or replace the items required. The laser repair was conducted by our highly experienced service engineer ‘Gavin Edwards’. The laser repair visit included: –
Initial Visit – Inspection and repair
Upon arrival at Wimbledon High School the machine was visually inspected. Even tho the laser machine had had the small fire it looked in good condition. The main item to incur damage within the laser machine is usually the laser head. This case was no exception. The red pointer had scorch marks on it’s outer housing, but was still functional. The internal lens and nozzle were inspected. Apart from a slight mark in the centre of the lens,, which was cleanable, the lens was ok. The O’ring holding the lens had to be replaced as it damaged.



As previously mentioned the fire happened whilst the customer was using the machine to cut corrugated card. One of the possible factors causing this fire would be the air assist. On this particular machine the nozzle aperture was measured and was shown to be 5.8mm in diameter. The nozzle aperture is not only for allowing the beam to pass through, but it is mainly to focus the air assist into a concentrated stream of air flow to assist in cutting. This aperture size is far too big. For comparison the nozzle aperture on a a Lightblade nozzle is 2.5mm in diameter.
Included in the air assist is, of course, the air pump itself. On this machine the air assist pump is rather small at a flow rate of 82 l/min. Again in comparison the air assist pumps supplied with all Lightblade‘s has a flow rate of 145 l/min.
There was nothing else wrong with the machine that was caused by the fire. The machine was now given some further checks to ensure optimal running.
- Inspect and Clean all Mirrors and Lens
- Inspect and re-align beam
- Water Cooling Chiller Inspection, Clean, Drain & Refill
The laser tube that was fitted was an EFR CL1800 80 watt tube which was dated 27 January 2019. Even though it was an older tube it was still producing 64.2 watts @100% from the nozzle.
The extractor system was inspected for any damage caused by the fire, none was found. This may have been down to the extractor being too small for this size of machine. The extraction pipework and connections were also checked, the vent at the back of the machine needed to be removed and cleaned


Whilst on site and running the final checks on the machine, it was noted that the chiller would alarm out on occasions. With an error code E05. This error means that the Flow rate is too low. Gavin checked all the external piping which was all fine. Drained the machine and restarted to remove any air blockages, This fixed the issue for about an hours worth of testing. Gavin then removed the outer housing of the chiller to check the internal pipework. One of the internal pipe had a small bend. This couldn’t be straightened. To avoid the chiller alarming constantly a new chiller would be recommended.
Follow-up Visit
With the information supplied in the first visit the customer requested a new chiller and a more powerful air pump. The old faulty chiller unit was drained and removed from the system. A new CW 5200 was installed and powered on to check for any leaks and air bubbles within the system.
The old air pump was removed and stored away and the new more powerful air pump was installed.


Several of the customer jobs were run on the machine to check it’s overall function and the customer was happy with the results produced.
Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser machine repair near Wimbledon capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.