Laser Machine Repair near Purley, on a 1290 80 watt HPC LaserScript Machine – Riddlesdown School
A visit to a customer, Riddlesdown Collegiate was required as the customer had informed us that the extraction unit was not removing smoke from the laser chamber on their machine. The laser repair was conducted by our highly experienced service engineer ‘Gavin Edwards’. The repair visit included: –
The day before the visit was organised the customer had reached out again to let us know that the laser would no longer power on.
Upon arrival at Riddlesdown Collegiate the machine was visually inspected. The machine electrical cabinet was first inspected, and it was found that the main circuit breaker had tripped. Resetting the circuit breaker enabled the machine to power on successfully. After extensive testing of the downstream components there was no obvious fault found.
On continuing the inspection a couple of other items were found: –
It was observed that the red diode pointer had previous had some damage to the wiring. It had been repaired with electrical tape. The damage was repaired with industry standard connection terminals.
On inspecting the water flow inside the laser tube, it was noted that there were a lot of air bubbles, floating through. This usually means that the water level in the chiller is too low and the pump is sucking in air into the cooling circuit.
It was also found that there was a small leak from the connector of the inlet to the water flow sensor. Due to the pipework being too short internally to the machine, so it couldn’t just be simply repaired. Instead this was repaired by connecting the chiller pipework directly into the water flow sensor, in order to achieve this a larger hole was required in the main chassis. This was drilled and a rubber grommet inserted to enable the silicon pipework to safely pass through.


Nothing else could be found wrong with the laser machine prior to testing, so the attention was turned to the extraction unit.
The Bofa AD Oracle iQ that had been supplied with the machine is underpowered for the size of the laser machine, so high flow rates are needed. The unit was set to a flow rate of 210. This was increased to the maximum flow rate of 380. The unit was not able to achieve this and triggered an alarm at 336 l/min. The extraction unit should still be able to achieve maximum flow rate, unless there is a blockage or reduction in available flow within the pipework. The main pipe was removed from the machine and the grill was inspected. It was approximately 75% blocked. This was cleaned and placed back into position.




The extraction machine was now able to reach maximum flow rate. The flow rate was reduced to 250l/min and the customer was advised to not operate the extraction unit at full power as if the extraction unit is set too high this not only impacts the efficiency of the extraction reduces the life span of the filters. We recommend having the extraction set as low as possible for your application and laser machine dimensions to enable long filter life and better efficiencies on power consumption.
Once all the reported issues were complete the laser machine was given a service to reduce future costs.
- Topped up the Water Cooling Chiller & cleaned filters
- Inspected and cleaned all mirrors, lenses and nozzle
- Inspect, Clean and Lubricate all Linear/Guide Rails
The laser power was checked from the Nozzle and was measured to be 73w @ 85%.


Several jobs were run on the machine to check it’s overall function..
Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our Laser machine repair near Purley capabilities or anywhere else in the country, or any other Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.