FluxCare – Flux Laser Repair Uk – Isle of Man – Flux Beambox 40w
A RTB ( Return To Base) repair request from our customer Jay. This customer resides on the Isle of Man and although a beautiful part of the country it doesn’t make repairing machines economical. So Thinklaser came up with FluxCare, whereby the customer can send their Flux Laser Machine to our site for a thorough service or repair.
Flux Beambox
The customers Flux Beambox arrived on site and the repair was conducted by our highly experienced service engineer Gavin Edwards.
The Beambox was initially checked over and the following issues were found. The main power switch, located at the back of the unit, was found to be faulty, therefore was replaced. The remainder of the external aspects of the machine were checked but were found to be of good repair.
The laser repair then journeyed into the internals of the machine.
On initial startup the X-axis movement seemed to be having a few issues, this issue was sourced to a worn pully on the X-belt. The was replaced with a new pulley and tested.

The laser power was checked from the output of the laser tube. This was measured at 10w. This indiciated an issue with the laser tube.

The laser tube was replaced with a SPT laser tubes.

As with any laser tube replacement, the system was fully aligned along all mirrors and down through the nozzle. Once completed the laser power was measured coming the nozzle. This was measured at 33w.
Continuing with repair of the Beambox. The camera imagery was not working as expected. On closer inspection it was found that the camera connector had a damaged pin. This was repaired and the camera reconnected.


Even with the connector repaired, the camera would not render the full image. The camera cable was then replaced and this fixed this issue.
The repaired continued with the following items checked without issue.
- Drain, flush and refill water reservoir
- Inspect, Clean and Lubricate all Linear/Guide Rails
- Clean Air Pump
- Clean Camera System
- Electronics Inspection
- Safety Interlocks Inspection & Test
During the rest of these service items it was found that the bed was not level, this was adjusted to be flat with the laser head moment, in order to maintain focus across the entire work piece.
The laser power was tested coming from the nozzle. It was showing 35w @70% power.
The machine was cleaned up and a number of jobs were tested and run. All remaining tests were successful and the machine repackaged and sent back to the happy customer.
Any of the consumable items mentioned above, Lens, Mirrors, Laser tubes, Power supplies are all available and can be bought separately in our online shop.
If you would like further information on our FluxCare Maintenance programme capabilities for anywhere in the country, or any other Laser Servicing, Laser Repair, Laser Training requirement or Laser Application, please request a call back or, talk to one of our service engineering specialists by going to our contact page – link below.