Description
The ‘best in class’ high-performance AD Oracle has now been further enhanced with BOFA’s Intelligent Operating System (iQ), combining a range of unique features into one compact unit, the AD Oracle iQ.
The Intelligent Operating System (iQ) performs at two distinct levels. Operators benefit from the ease of operation and clarity of real-time information, the system also provides a cache of analytical data, enabling users to download performance and operating parameters for evaluation purposes.
Standard Features for AD Oracle iQ
- Reverse flow filter technology
- Auto sensing voltage (100-230v) for global use
- Automatic flow control
- Advanced Carbon Filter technology
- HEPA and gas combined filter
- High contrast display
- Real time airflow reading
- Independent filter condition monitoring
- Filter status warnings
- ‘Run safe’ operation
- Remote diagnostics via USB
Optional Features for AD Oracle iQ
- VOC gas sensor (Volatile Organic Compound)
- This sensor and alarm are optional extras on some systems. If the VOC (Volatile Organic Compound) alarm option is installed in your unit, the extractor will monitor and detect the level of VOC particles in the air. If the VOC level rises above a pre-set level then the LED will flash red and alarm will sound. This will then require the replacement of the Combined filter.
- Remote stop / Start interface
- The Remote Stop/Start feature enables the extraction unit to be remotely turned On / Off via an external signal. This feature can be configured in 3 ways
- DC Voltage input – Range 12-24VDC
- Volt free input – Open / Closed contacts
- Override – Stop / Start feature switched off
- The Remote Stop/Start feature enables the extraction unit to be remotely turned On / Off via an external signal. This feature can be configured in 3 ways
- Filter Blocked / System Fail Signal
- With this option the system will output a signal to alert the user when the extractor has failed or when the filters are blocked. This feature will not directly stop the extractor from running, correctly, but if fitted this feature should be terminated correctly before power is applied to the system. With this configuration the Filter blocked & System fail signals will be linked together to give a combined single output.
- On-board Compressor (POA)
- Optional filter medias
Technical Data
Dimensions (HxWxD): 975 x 455 x 505mm
Airflow /Pressure: 380m3/hr | 96mbar
Electrical Data: 90v – 257v 1ph 50/60Hz Full load current: 12.5 amps / 1.1kw
Weight: 65kg
Approvals: CE